IDA Loop Antenna, H-Field (Shielded loop antenna, 9 kHz to 30 MHz)

3100/14

New product

This low-frequency loop antenna is particularly suitable for detecting defective or poorly screened switched power supplies or electrical controllers that emit interference, and for identifying interference due to power line carrier systems, or demonstrating interference with other signals in the very low frequency range (ultra long wave).

More details

Narda Safety Test Solutions

 

)

Directional characteristic

H = horizontal, V = vertical.

Product Features

  • High measurement sensitivity
  • Pronounced figure of eight directional characteristic, ideal for directional null direction finding
  • Mechanically robust
  • Light and easy to handle

This low-frequency loop antenna is particularly suitable for detecting defective or poorly screened switched power supplies or electrical controllers that emit interference, and for identifying interference due to power line carrier systems, or demonstrating interference with other signals in the very low frequency range (ultra long wave).

The loop antenna registers the magnetic field within the frequency range from 9 kHz to 30 MHz and has unusually high sensitivity with a typical antenna factor of 47.5 dB(1/m) at 1 MHz.

Mõõdud 430 mm x 370 mm x 42 mm (without handle)
Kaal 380 g (without handle)
Sageduste vahemik 9 kHz to 30 MHz

Hetkel pole ühtegi ülevaadet

Kirjutage oma ülevaade

IDA Loop Antenna, H-Field (Shielded loop antenna, 9 kHz to 30 MHz)

IDA Loop Antenna, H-Field (Shielded loop antenna, 9 kHz to 30 MHz)

This low-frequency loop antenna is particularly suitable for detecting defective or poorly screened switched power supplies or electrical controllers that emit interference, and for identifying interference due to power line carrier systems, or demonstrating interference with other signals in the very low frequency range (ultra long wave).

Description Language Ver. Link
Datasheet IDA 2 English NSTS 0716-E0305D IDA 2 Datasheet, EN
Datasheet RF Filters English NSTS 0417-E0321B Filters Datasheet, EN
Brochure IDA 2 English NSTS 04/17 E0330A IDA 2 Brochure, EN
Flyer IDA in action at major events English NSTS 0812 ME-E0299A IDA in action Flyer, EN
IDA 2 Commands English V 3.1.0 IDA 2 Commands, EN
Flyer IDA 2 - HiRes Spectrum Analyzer English NSTS 0317-D0325A IDA 2 Flyer, EN
Technical Note: IDA 2 Horizontalscan English TN100 TN: Horizontal Scan, EN
Technical Note: IDA 2 Interference Localization English TN102 TN: Interference Localization, EN
Technical Note: IDA 2 IQ Analyzer English TN103 TN: IQ Analyzer, EN
Technical Note: IDA 2 Attenuator English TN104 TN: Attenuator, EN
Technical Note: IDA 2 User generated maps English TN105 TN: Maps, EN
Technical Note: IDA 2 Receiver and Spectrum Analyzer English TN106 TN: Receiver, EN
Technical Note: IDA 2 HiRes Spectrogram English TN107 TN: Spectrogram, EN
Technical Note: IDA 2 Revealing Interference English TN108 TN: Interference, EN
Technical Note: IDA 2 Filter/td> English TN110 TN: Filter, EN
Technical Note: IDA 2/NRA IQ Data English TN101 TN: IQ Data, EN
Technical Note: IDA 2 Datarate Responsetime English TN1103 TN: Responsetime, EN
Application Note: IDA 2 GSM Intermodulation English 1074 AN: Intermodulation, EN
Application Note: IDA 2 Interference Measurement and Localization English 1057 AN: Interference, EN
Application Note: IDA 2 Jammer English 1076 AN: Jammer, EN
Application Note: IDA 2 Multitransmitter Airport Stuttgart English 1061 AN: Multitransmitter, EN
Application Note: IDA 2 - Demosoftware - General English TN1105 AN: Demo, EN

IDA 2 - How to analyze GSM/2G with the Narda IDA2 Spectrum and Signal Analyzer

 

IDA 2 - Direction Finding, Geolocation, Horizontal Scan and Radio Bearing in the Narda IDA

 

IDA 2 - Understanding 4G LTE on the air interface with the IDA2

 

IDA - Multi Channel Table and Transmitter Table Features

 

IDA 2 - How to use the IDA as an oscilloscope in Time Domain / Scope Mode

 

IDA 2 - Creating screenshots and saving data in the IDA from narda

 

IDA 2 - Record or store measuring data automatically with the IDA

 

 

IDA 2 - How to optimize or customize Your measuring view on the IDA display