_Shablon View larger

Nardalert S3

2271/131

New product

Personal radiation monitor for electric fields with on site interchangeable sensor modules

Nardalert S3 is worn on the body and gives visible, audible and vibratory warning when the electric field power density approaches or exceeds the permitted limit. The warning thresholds are user settable. Different sensor modules that can be exchanged on site are available for for various human safety standards.

More details

Narda Safety Test Solutions

 

)

Personal radiation monitor for electric fields with on site interchangeable sensor modules

Nardalert S3 is worn on the body and gives visible, audible and vibratory warning when the electric field power density approaches or exceeds the permitted limit. The warning thresholds are user settable. Different sensor modules that can be exchanged on site are available for for various human safety standards.

Sensor modules are available for the following human safety standards:

  • ACGIH Industry
  • ARPANSA RP S3, occupational
  • BGV B11, 2001, EXP.1 (occupational)
  • Canada Safety Code 6 (2015)
  • ENV 50166-2, occupational
  • EU Directive 2013/35
  • FCC 1997 occupational / controlled
  • IEEE C95.1-2005/ANSI C95.1-2005 controlled
  • Japan RCR-38 controlled
  • NATO CG95.1-2345-2014

PRODUCT FEATURES:

  • Automatic evaluation of exposure frequencies according to human safety standard
  • LCD on top of casing can be seen at a glance
  • Display of distribution of high and low frequency components
  • Data logger option
  • USB interface for battery charging and downloading measurement data
  • Calibration interval: 4 years for Mainframe and 2 years for Sensors

Mõõdud 117 x 82.6 x 31.8 mm
Kaal 230 g
Sageduste vahemik 100 kHz bis 50 GHz

Hetkel pole ühtegi ülevaadet

Kirjutage oma ülevaade

Nardalert S3

Nardalert S3

Personal radiation monitor for electric fields with on site interchangeable sensor modules

Nardalert S3 is worn on the body and gives visible, audible and vibratory warning when the electric field power density approaches or exceeds the permitted limit. The warning thresholds are user settable. Different sensor modules that can be exchanged on site are available for for various human safety standards.

Nardalert S3 Basic set

1. Nardalert S3 Mainframe, including battery (2270/01)
2. Carrying case, holds monitor, charger and accessories (2400/90.06)
3. Power supply 5 VDC, 100 V-240 VAC (70890000)
4. Belt Clip, non-conductive (11229310)
5. Lanyard Clip, non-conductive (11229312)
6. Cable, USB interface for NS3, 1 m (70889004)
7. Software, NS3-TS, PC transfer (2270/93.01)
8. Operating manual NS3 (43067900)
9. Certificate of calibration

Choise of sensor modules:

.. with FCC Sensor Module 2271/101
...with IEEE Sensor Module 2271/111
...with SC6 Sensor Module 2271/121
...with ICNIRP Sensor Module

Individual Sensor Modules (without Nardalert S3 Mainframe)

Sensor Module, FCC 1997 “Occupational/Controlled” 2271/01
Sensor Module, IEEE C95.1-2005, “Controlled” 2271/11
Sensor Module, Safety Code 6, “Controlled” 2271/21
Sensor Module, ICNIRP 1998, “Occupational” 2271/31

OPTIONS

Nardalert S3 Optioned Model (enables Data Logging, Histogram and Alarm Varying)

Samas kategoorias on veel 1 toode :