The RadMan 2LT and RadMan 2XT Radiation Monitors are warning devices for the protection of people who work in areas where increased levels of electromagnetic radiation are present. Broadcasting, telecommunications and radar antennas are sources of strong electromagnetic fields. The device is worn on the body and warns its user in good time before the permitted limit values are exceeded.
The actual field exposure level is indicated in six steps from 5% to 200% by LEDs. The percentages refer to the proportion of the power density limit value specified in a safety standard. If the field exposure level exceeds 50% of the limit value, the device vibrates and emits a loud alarm tone. There is also a bright light in the top part of the RadMan 2 that can be easily seen from various angles. The light flashes red in time with the alarm signal. A second, more persistent alarm sounds when the 100% threshold is exceeded, warning the user to leave the danger area.
The permitted limit values specified in the standards vary according to the frequency. Weighting filters in the sensors of the RadMan 2 simulate the frequency response of the standard. They ensure that the alarm thresholds are correct over the entire frequency range. Settings are not necessary.
Personal monitors are generally worn on the person. RadMan 2 is supplied fitted with a suitable attachment and RF absorber that allows it to be fixed easily to a harness or belt. The RF absorber reduces the signal reflections caused by the body which would otherwise affect the result displayed by the monitor. If needed, the RadMan 2 can be released from the attachment with one hand in order to determine the field exposure away from the body with an isotropic directional characteristic.
RadMan 2 LT or XT unit
Cable USB 2.0
Mounting adapter
Carrying case for RadMan 2
Clip-On Lanyard
Tool, Allen Wrench, 1.5 mm
Fastening strap 25mm x 200mm
Operating manual RadMan 2LT/2XT
Tripod, Benchtop 0.16m, non-conductive
Handle, non-conductive, 0.42m
Car Charger Adapter, USB 5V
Power Supply (Europe), USB 5V
Power Supply (UK), USB 5V
* ICNIRP Occupational versions are also compliant with many national and international standards and regulations such as Directive 2013/35/EU, EMFV 2016 (Germany) and VEMF 2016 (Austria).
Batteries | 2 replaceable NiMH batteries type AA, rechargeable via USB port |
Operating time | 800 hrs. (without alarm) / charging time less than 8 hrs. |
Dimensions | 165 x 47 x 31 mm without mounting adapter |
Weight | 185 g without mounting adapter |
Frequency | E-Field: XT - 900 kHz to 60 GHz (ICNIRP models); LT - 50 MHz to 8 GHz. H-Field: XT - 27 MHz to 1 GHz (ICNIRP, SC6 models); LT - 50 MHz to 1 GHz. |
Protection class | IP65 (dust-tight and protected against water jets) |
Operating conditions | -10 °C to +55 °C, 5% to 95%, non-condensing (≤ 29 g/m³, IEC 60721-3-2 class 7K2) |
Storage conditions | -40 °C to +70 °C, 5% to 95%, non-condensing (≤ 29 g/m³, IEC 60721-3-2 class 7K2) |
Frequency range | 1 MHz to 40 GHz (E-field); 27 MHz to 1 GHz (H-field) |
Car Charger With Qualcomm Quick Charge 3.0 Technology Charge compatible devices up to 4x faster than traditional chargers. Backwards compatible with all versions of Qualcomm Quick Charge Technology (1.0, 2.0 & 3.0). Quick charge 2.0 enables charger speed up to 75% faster than conventional technology
No customer reviews for the moment.
Description | Language | Ver. | Link |
RadMan 2 Technical description | English | NSTS 0219-E0347B | RadMan 2 Datasheet, EN |
Human Safety Leaflet | English | Human Safety Leaflet, EN | |
Safety at Work | English |
NSTS 06/16-ME-E324A |
Safety at Work Flyer, EN |